BAM High Voltage Power Capacitor
Aikace-aikace da Matsayi:
Babban ƙarfin wutar lantarki ana amfani dashi a cikin tsarin wutar lantarki na AC tare da 50Hz don inganta yanayin wutar lantarki. Ayyukan aikin sun zama GB 3083.2-89 《High ƙarfin lantarki shunt capacitor》 da IEC60871-1987.
GB/T11024-2010 National Standard 《Rated ƙarfin lantarki 1kV ko sama da shunt capacitors na AC ikon tsarin
JB/7112-2000 Ma'aunin Masana'antar Injin 《Haɗaɗɗen HV Shunt Capacitor
DL/T628-1997 Matsayin Masana'antar Wutar Lantarki 《Haɗaɗɗen HV Shunt Capacitor Buƙatun Fasaha》
Yanayin Amfani:
1.Altitude: kasa da 1000m; Yanayin yanayi: -40 ℃ ~ +40 ℃.
2.No tashin hankali inji vibration, babu cutarwa gas da tururi, babu lantarki, da fashewar, da kuma fashewar ƙura a wuri.
3.Ci gaba da ƙarfin aiki: 1.00 Un, max na dogon lokaci, Sama da ƙarfin lantarki: less.1 Un.
4.Stable over-curent (gami da harmonics current) kasa da 1.3 In.
5.With tsayawar ƙarfin lantarki: tsakanin m 2.15, lokacin rated ƙarfin lantarki don 10 seconds, tsakanin tashoshi da ganga 42kV for 10 seconds.
Babban halayen fasaha:
1.Rated ƙarfin lantarki: 6.3kV, 6.6kV, 6.6 / √3kV, 7.96kV, 10.5kV, 11kV, 11kV, 11/√3kV, da fatan za a nuna a cikin tsari idan kana son sauran na musamman iya aiki.
2.Rated iya aiki: 33 ~ 334kvar da fatan za a nuna a cikin tsari idan kuna son sauran iya aiki na musamman.
3.Capacity haƙuri: -5 ~ 15%.
4. Loss angel tangential darajar: fim & papaer matsakaici tg θ≦0.08%, fim matsakaici tg θ≦0.05%.
5.Withstand irin ƙarfin lantarki: zai iya iya AC2.15 ko DC4.3 sau rated irin ƙarfin lantarki tsakanin iya aiki pales, karshe game da 10s ba tare da karya ko flash, BIL: 6kV (30kV), 10kV (42Kv).
6.Free fitarwa: yana da juriya na ciki, 10min bayan yanke wutar lantarki, ragowar ƙarfin lantarki zai rage zuwa 75V daga √2 Un.
7.Max. A halin yanzu: yana gudana cikin kwanciyar hankali a ƙarƙashin ƙimar ƙarfin lantarki na lokaci 1.3, sama da ƙarfin lantarki, ingantaccen haƙuri da igiyar jituwa wanda ba zai iya wuce min 1 kowane awanni 24 ba.
8.Max.Current: gudana smoothly a karkashin 1.3 lokaci rated ƙarfin lantarki, a kan ƙarfin lantarki, iya aiki tabbatacce haƙuri da kuma jituwa kalaman wanda ba zai iya 1.43 lokaci rated halin yanzu.
9.Standard: GB/T 112024.1-2001, IEC6087:1997.
SAURAN WUTA WUTA
Samfura BAM | Ƙimar Wutar Lantarki (kV) | Fitarwa mai ƙima (kVar) | Ƙarfin Ƙarfi (uF) | Wanda aka ƙididdigewa a cikin (A) na yanzu |
6.3-25-1W | 6.3 | 25 | 2.006 | 3.968 |
6.3-30-1W | 6.3 | 30 | 2.406 | 4.762 |
6.6/√3-25-1W | 6.6/√3 | 25 | 5.481 | 6.561 |
6.3/√3-30-1W | 6.6/√3 | 30 | 6.577 | 7.873 |
6.3/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
10.5-25-1W | 10.5 | 25 | 0.722 | 2.38 |
10.5-30-1W | 10.5 | 30 | 0.886 | 2.857 |
10.5-50-1W | 10.5 | 50 | 1.444 | 4.762 |
11/√3-30-1W | 11/√3 | 30 | 2.368 | 4.724 |
11/√3-50-1W | 11/√3 | 50 | 3.946 | 7.873 |
6.3-30-1W | 6.3 | 30 | 2.4 | 4.76 |
6.3-50-1W | 6.3 | 50 | 4 | 7.9 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | ashirin da hudu | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
10.5-50-1W | 10.5 | 50 | 1.44 | 4.8 |
10.5-100-1W | 10.5 | 100 | 2.9 | 9.5 |
10.5-150-1W | 10.5 | 150 | 4.3 | 14.3 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-300-1W | 10.5 | 300 | 8.67 | 28.6 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |
11/√3-50-1W | 11/√3 | 50 | 3.95 | 7.87 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
6.6/√3-50-1W | 6.6/√3 | 50 | 10.96 | 13.12 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11-100-1W | 11 | 100 | 2.63 | 9.1 |
11-150-1W | 11 | 150 | 3.95 | 13.6 |
11-200-1W | 11 | 200 | 5.26 | 18.2 |
11-300-1W | 11 | 300 | 7.89 | 27.3 |
11-334-1W | 11 | 334 | 8.79 | 30.4 |
12-100-1W | 12 | 100 | 2.2 | 8.33 |
12-150-1W | 12 | 150 | 3.3 | 12.5 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-300-1W | 12 | 300 | 6.64 | 25 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
12/√3-100-1W | 12/√3 | 100 | 6.63 | 14.4 |
12/√3-150-1W | 12/√3 | 150 | 9.95 | 21.7 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-300-1W | 12/√3 | 300 | 19.9 | 43.3 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12/√3-400-1W | 12/√3 | 400 | 26.54 | 57.74 |
6.3-100-1W | 6.3 | 100 | 8 | 15.9 |
6.3-150-1W | 6.3 | 150 | 12 | 23.8 |
6.3-200-1W | 6.3 | 200 | 16 | 31.7 |
6.3-300-1W | 6.3 | 300 | ashirin da hudu | 47.6 |
6.3-334-1W | 6.3 | 334 | 26.8 | 53 |
6.6-100-1W | 6.6 | 100 | 7.3 | 15.2 |
6.6-150-1W | 6.6 | 150 | 11 | 22.7 |
6.6-200-1W | 6.6 | 200 | 14.6 | 30.3 |
6.6-300-1W | 6.6 | 300 | ashirin da biyu | 45.5 |
6.6-334-1W | 6.6 | 334 | 24.4 | 50.6 |
6.6/√3-100-1W | 6.6/√3 | 100 | 21.9 | 26.24 |
6.6/√3-150-1W | 6.6/√3 | 150 | 32.9 | 39.36 |
6.6/√3-200-1W | 6.6/√3 | 200 | 43.8 | 52.48 |
6.6/√3-300-1W | 6.6/√3 | 300 | 65.8 | 78.7 |
6.6/√3-334-1W | 6.6/√3 | 334 | 73.2 | 87.6 |
11/√3-100-1W | 11/√3 | 100 | 7.89 | 15.75 |
11/√3-150-1W | 11/√3 | 150 | 11.84 | 23.6 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-300-1W | 11/√3 | 300 | 23.68 | 47.2 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
11-100-1W | 11 | 100 | 2.63 | 5.25 |
11-150-1W | 11 | 150 | 3.95 | 7.87 |
11-200-1W | 11 | 200 | 5.26 | 10.5 |
11-300-1W | 11 | 300 | 7.9 | 15.75 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.3 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
12-100-1W | 12 | 100 | 2.2 | 4.8 |
12-150-1W | 12 | 150 | 3.2 | 7.2 |
12-200-1W | 12 | 200 | 4.4 | 9.6 |
12-300-1W | 12 | 300 | 6.64 | 14.45 |
11/√3-200-1W | 11/√3 | 200 | 15.78 | 31.5 |
11/√3-334-1W | 11/√3 | 334 | 26.36 | 52.6 |
12/√3-200-1W | 12/√3 | 200 | 13.3 | 28.9 |
12/√3-334-1W | 12/√3 | 334 | 22.1 | 48.2 |
12-200-1W | 12 | 200 | 4.4 | 16.7 |
12-334-1W | 12 | 334 | 7.39 | 27.8 |
10.5-200-1W | 10.5 | 200 | 5.8 | 19 |
10.5-334-1W | 10.5 | 334 | 9.65 | 31.8 |