• sns01
  • sns03
  • sns02

Cire Cire

  • GW-12 Outdoor AC HV Disconnect Switch

    GW-12 Wajen AC HV Cire Yankewa

    GW □ -12outdoor AC HV cire haɗin canzawa (cire haɗin cirewa don gajeren anan) ana amfani dashi a cikin tsarin wutar lantarki tare da madaidaicin mita 50Hz, ƙarfin ƙarfin ƙarfin 12kV, yafi yawa don yin ko keta madaidaiciya a ƙarƙashin layin da ke samar da wutar lantarki a cikin kayan wutar lantarki mai girma na waje. Wani nau'in sauya haɗin hanyar gurɓataccen gurɓataccen yanayi zai iya magance ƙazamar ƙazamar aiki yayin aiki don biyan buƙatun masu amfani a cikin ƙazantar yankin.
  • GW9-24 Outdoor AC HV Disconnect Switch

    GW9-24 Canji AC HV Cire Cire Ciki

    Jerin GW9-24 (W) canzawa HV cire haɗin canza tsarin tsari ne guda ɗaya, wanda ake amfani dashi don buɗewa ko rufe da'irori a ƙarƙashin ƙarfin lantarki amma babu nauyin kaya a cikin tsarin lantarki na waje 24kV. Yana da tsayayyen zana ƙugiya da na'urar kulle kai, da tasirin aiki tare da sandar ƙugiya. Morearin ƙari, canzawar nau'in gurɓataccen gurɓataccen gurɓataccen yanayi zai iya magance walƙiya saboda gurɓatarwa yayin aiki na cire haɗin canzawa don biyan buƙatun masu amfani a cikin mummunan ƙazantar yankin.
  • GW5-40.5 DISCONNECT SWITCH

    GW5-40.5 DISCONNECT SWITCH

    Ana amfani da GW5-40.5 mai sauya wutar lantarki mai cire wutar lantarki ta waje don yin ko karya madaidaicin ƙarfin lantarki a cikin ƙarfin ƙarfin 40.5kV, tsarin AC 50 / 60Hz. Yana iya buɗewa da rufe ƙaramin ƙarfin da yanayin aiki.
  • GW4-40.5 DISCONNECT SWITCH

    GW4-40.5 RUFE GYARA

    GW4 nau'in serial high voltage disconnect switch yayi daidai da buƙatu a cikin GB1985-2004 High-voltage AC Mai cire sauya da sauya sauyawa, IEC62271-102: 2002AC Disconnecting Switches da Earthing Switches, da IEC60694: 1996 Magana gama gari don High voltage Switchgear and Control Devices.
  • GN30-12(D) Series  Indoor High Voltage Disconnect Switch

    GN30-12 (D) Siginan Yanayin Babban Haɗa Yankan Ciki

    GN30-12 (D) cire haɗin canzawa kayan lantarki ne na cikin gida na ƙarfin ƙarfin ƙarfin 12kV, mai fasali uku AC50 / 60Hz. Ana amfani dashi don yin hutu da canza halin yanzu don kayan lantarki na HV a ƙarƙashin yanayi tare da ƙarfin lantarki da babu-caji. Mai sauya yana amfani da lambar tuntuɓar juyawa wacce aka ɗora akan mai sauyawa cikin sauƙi. Yana da
    yana ɗaukar bango ta hanyar shigarwa kuma
  • GN19-12(C) Series  Indoor High Voltage Disconnect Switch

    GN19-12 (C) Siginan Yanayin Babban Haɗa Yankan Ciki

    GN19-12 (C) HV cire haɗin canzawa ya shafi tsarin wuta na ƙarfin ƙarfin ƙarfin 12kV, AC 50 / 60Hz. An sanye shi da kayan aiki na hannu na CS6-1 kuma ana amfani dashi don karyewa da yin da'ira a ƙarƙashin mara nauyi. Akwai ƙarin nau'in gurɓata, nau'in mai tsayi da nau'in nuna ƙarfi.