• sns01
  • sns03
  • sns02

MV Canja

  • FZW32-24 Series Outdoor High Voltage Isolating Vacuum Load Break Switch

    FZW32-24 Jerin Kayan Wuta Mai dooraukaka Na Keɓe Varfin adarya Hanya

    1. Shaci FZW32-24 nau'in waje mai tsananin karfin lantarki wanda yake kewayawa kayan sauya kaya shine wani sabon nau'in sauya kaya wanda shine hadewar kwarewar kwarewar sauyawar kayan cikin gida da kuma fasahar kere kere ta waje. Wannan sauyawar sauyawar kayan an haɗa shi da katsewa, mai katsewa ta iska da injin aiki da sauran sassan. Ta amfani da ƙa'idar katsewa na injin, tare da ƙarfin arcing mai ƙarfi, aikin dogaro, tsawon rayuwar sabis, ƙarami kaɗan, babu haɗarin fashewa, ...
  • GW-12 Outdoor AC HV Disconnect Switch

    GW-12 Wajen AC HV Cire Yankewa

    GW □ -12outdoor AC HV cire haɗin canzawa (cire haɗin cirewa don gajeren anan) ana amfani dashi a cikin tsarin wutar lantarki tare da madaidaicin mita 50Hz, ƙarfin ƙarfin ƙarfin 12kV, yafi yawa don yin ko keta madaidaiciya a ƙarƙashin layin da ke samar da wutar lantarki a cikin kayan wutar lantarki mai girma na waje. Wani nau'in sauya haɗin hanyar gurɓataccen gurɓataccen yanayi zai iya magance ƙazamar ƙazamar aiki yayin aiki don biyan buƙatun masu amfani a cikin ƙazantar yankin.
  • GW9-24 Outdoor AC HV Disconnect Switch

    GW9-24 Canji AC HV Cire Cire Ciki

    Jerin GW9-24 (W) canzawa HV cire haɗin canza tsarin tsari ne guda ɗaya, wanda ake amfani dashi don buɗewa ko rufe da'irori a ƙarƙashin ƙarfin lantarki amma babu nauyin kaya a cikin tsarin lantarki na waje 24kV. Yana da tsayayyen zana ƙugiya da na'urar kulle kai, da tasirin aiki tare da sandar ƙugiya. Morearin ƙari, canzawar nau'in gurɓataccen gurɓataccen gurɓataccen yanayi zai iya magance walƙiya saboda gurɓatarwa yayin aiki na cire haɗin canzawa don biyan buƙatun masu amfani a cikin mummunan ƙazantar yankin.
  • GW5-40.5 DISCONNECT SWITCH

    GW5-40.5 DISCONNECT SWITCH

    Ana amfani da GW5-40.5 mai sauya wutar lantarki mai cire wutar lantarki ta waje don yin ko karya madaidaicin ƙarfin lantarki a cikin ƙarfin ƙarfin 40.5kV, tsarin AC 50 / 60Hz. Yana iya buɗewa da rufe ƙaramin ƙarfin da yanayin aiki.
  • GW4-40.5 DISCONNECT SWITCH

    GW4-40.5 RUFE GYARA

    GW4 nau'in serial high voltage disconnect switch yayi daidai da buƙatu a cikin GB1985-2004 High-voltage AC Mai cire sauya da sauya sauyawa, IEC62271-102: 2002AC Disconnecting Switches da Earthing Switches, da IEC60694: 1996 Magana gama gari don High voltage Switchgear and Control Devices.
  • GN30-12(D) Series  Indoor High Voltage Disconnect Switch

    GN30-12 (D) Siginan Yanayin Babban Haɗa Yankan Ciki

    GN30-12 (D) cire haɗin canzawa kayan lantarki ne na cikin gida na ƙarfin ƙarfin ƙarfin 12kV, mai fasali uku AC50 / 60Hz. Ana amfani dashi don yin hutu da canza halin yanzu don kayan lantarki na HV a ƙarƙashin yanayi tare da ƙarfin lantarki da babu-caji. Mai sauya yana amfani da lambar tuntuɓar juyawa wacce aka ɗora akan mai sauyawa cikin sauƙi. Yana da
    yana ɗaukar bango ta hanyar shigarwa kuma
  • FZW32-40.5(RD) Series Outdoor High Voltage Vacuum Load Break Switch

    FZW32-40.5 (RD) Jerin Kayan Wuta Mai Higharfin doorarfin Jirgin Sama

    FZW32-40.5 na waje AC babban ƙarfin lantarki cire haɗin sauya kayan sauyawa sabon abu ne wanda ke ɗaukar ƙwarewar kayan aiki na cikin gida da ke ciki da ƙarancin fasahar ƙetare zuwa ƙirar waje da ƙirar mutum. sauya fasalin kayan ya kunshi cire haɗin ruwa, mai dakatar da injiniya da kuma aikin aiki. uumarjin baka, akwai fa'idodi kamar ƙarfin kashe baka, ƙarfin aiki, tsawon rai, ƙarami kaɗan, babu haɗari mai fashewa kuma babu ƙazantar lalacewa ...
  • GN19-12(C) Series  Indoor High Voltage Disconnect Switch

    GN19-12 (C) Siginan Yanayin Babban Haɗa Yankan Ciki

    GN19-12 (C) HV cire haɗin canzawa ya shafi tsarin wuta na ƙarfin ƙarfin ƙarfin 12kV, AC 50 / 60Hz. An sanye shi da kayan aiki na hannu na CS6-1 kuma ana amfani dashi don karyewa da yin da'ira a ƙarƙashin mara nauyi. Akwai ƙarin nau'in gurɓata, nau'in mai tsayi da nau'in nuna ƙarfi.
  • PGS Series Outdoor High Voltage SF6 Load Break Switch

    PGS Series Out voltage Babban awon karfin wuta SF6 Load Break Break

    Ana amfani da PGS-630A sandar da aka sanya wajan hutu na karyewa don karya karfin wutar lantarki 12/24 / 40.5kV, wanda aka ƙaddara 630A, 50 / 60Hz tsarin rarraba wutar lantarki, halin rufewa na yanzu da kan ƙarfin wutar lantarki na yanzu, zai iya raba sassan waƙa ta atomatik rarrabawar wutar lantarki wacce kurakurai ke faruwa. Canjin ya dace da mai sarrafa lantarki wanda ke tare da sabuwar fasaha. Mai sauyawa yana da jagora, mota, yanayin aiki mai nisa. Za'a sanya mai sarrafa lantarki a cikin tabon ...
  • FZW32-12 Series Outdoor High Voltage Disconnecting Vacuum Load Break Switch

    FZW32-12 Jerin Kayan Wuta Mai dooraukaka Na Yanki Yanke Yanke Hutun Hutu

    1. Shaci FZW32-12 nau'in waje mai tsananin karfin wuta wanda yake cire rariyar hutu kayan sauya sabon nau'I ne na sauya kaya wanda shine hadewar kwarewar kwarewar sauyawar kayan cikin gida da kuma fasahar kere kere ta waje. Wannan sauyawar sauyawar kayan an haɗa shi da katsewa, mai katsewa ta iska da injin aiki da sauran sassan. Ta amfani da ƙa'idar katsewa na injin, tare da ƙarfin arcing mai ƙarfi, aikin dogaro, tsawon rayuwar sabis, ƙarami kaɗan, ba fashewar rawa ...
  • FZRN21-40.5 Indoor High Voltage Air Load Break Switch

    FZRN21-40.5 Canjin Hutun Jirgin Sama Na Cikin Gida Mai Sauƙi

    Yanayin muhalli 1. Tsayi: 1000m; 2. Yanayin yanayi: -40 ~ + 40 ℃; 3. Yanayin dangi: kimanin kashi 95% na yau da kullun, matsakaita kowane wata 90%; 4. Girgizar Kasa mai karfi: digiri 8; 5. Gurbataccen gurbatacce: Digiri na II. Sigogin fasaha NO. Abubuwan itaidaita 1imar Daraja 1 Rated ƙarfin lantarki kV 40.5 2 Rated mita Hz 50 3 Matsakaicin darajar halin yanzu na fis A 63 4 1min mitar ƙarfin ƙarfin ƙarfin ƙarfin ƙarfin kV 95/110 5 Walƙiyar motsi ƙarfin juriya ƙarfin lantarki kV 185/215 6 Girman da aka ƙayyade yana iya jure halin yanzu kA 50 7 .. .
  • FZN25-12 Series Indoor High Voltage Vacuum Load Break Switch

    FZN25-12 Jerin Jirgin Ruwan Higharfin Hanya na Cikin Cikin Gida

    FZN25-12 na cikin gida HV injin cire buɗaɗɗen kayan hutu mai canzawa 3-AC AC 50Hz 12kV kayan aikin cikin gida .. mechanism Tsarin sarrafawa: inji mai amfani da bazara, nau'in hannu da nau'ikan lantarki akwai; Type Nau'in aiki: operati na dama akan aikin hagu; Direction Jagorar aiki: hagu aiki, dama aiki; ♦ Aikace-aikace: na cikin gida 12kv switchgear. Yanayin Muhalli temperature Yanayin yanayi: -25 ° C 〜 + 40 ° C; Tsawo: <1000m (sama da matakin teku); ♦ Yanayin dangi: matsakaiciyar rana <95%, av kowane wata ...